Reviewed by rulesVerdict: NotableA State-Level Assessment of Space Weather Impact on the Virginia Power Grid: From Vulnerability to Mitigation Strategies
Contemporary methodologies exist for assessing the nationwide impacts of geomagnetically induced currents (GICs), such as the Coupled Space Weather Impact Model (C-SWIM), which links power grid vulnerability with…
Key numbers
- 6 hours and transformer replacement
- 365 days
Caveats
- Preprint; not yet peer reviewed.
VerdictWorth a reader's time today.
Abstract
Contemporary methodologies exist for assessing the nationwide impacts of geomagnetically induced currents (GICs), such as the Coupled Space Weather Impact Model (C-SWIM), which links power grid vulnerability with economic losses. Yet regional mitigation requires adapting the national model to the local transmission network so operators and planners can identify substations at risk and evaluate economic and population consequences and protective actions. We present the first adaptation of C-SWIM to Virginia, modeling the Pennsylvania-New Jersey-Maryland (PJM) Interconnection, which includes Dominion Energy Virginia and Appalachian Power. Its extra high voltage network was assessed under the May 2024 Gannon, October 2003 Halloween, and March 2015 St. Patrick's Day storms in addition to nine return period scenarios derived from statistical fits to 92 historical events. Using the Leontief consumption and production input-output model, we estimated daily losses of USD 145.5M for a 100-year storm and USD 230.6M for a 250-year storm, with 339,000-535,000 people and up to 12,000 businesses at risk of power outage. The Ghosh input-output model was used to evaluate three island selection algorithms for protective islanding, which temporarily disconnects parts of the grid to reduce transformer damage. Only one algorithm yielded benefits exceeding costs across all twelve scenarios, with avoided losses up to USD 9.69M per day and a cost of USD 0.204M per intervention. However, these islanding benefits assume disconnection for 6 hours and transformer replacement after 365 days. Moreover, the analysis uses national economic relationships and models only transformer thermal failure, excluding voltage collapse, cascading failures, and restoration. Transmission operators and state energy policymakers can use this statewide assessment to prioritize regional monitoring and appraise protective islanding.
The editor's rubric
- Leverage3 / 5
- A method or resource many groups across the field will adopt within a year.
- Magnitude3 / 5
- Large gain: roughly 2x, or a clear new state of the art on a hard, unsaturated problem.
- Evidence3 / 5
- Solid: multiple benchmarks or cohorts, ablations, fair baselines, released code or data.
- Novelty2 / 5
- A new combination of known ideas.
- Trajectory2 / 5
- Some room to improve with obvious engineering.
- Stakes3 / 5
- Meaningful benefit to many people within a few years.
Editor’s rationale
Heuristic triage from title and abstract text only, not a reading of the paper. Cues found: method (we propose); gains (outperforms); stakes (energy, climate).
How the score was computed
Desks place stronger verdicts first, then use this score to order work within the same verdict.
- Merit
- 5.5 / 10
- Adjusted merit
- 4.6 / 10
- Attention
- 0%
- Freshness
- 57%
- Citations0 (reference 15, via semantic-scholar, Nov 24, 2026, 06:45 UTC)